SLP HT 2D LiDAR for non-contact measurements on hot surfaces

SLP HT 2D LiDAR for non-contact measurements on hot surfaces

 

 

SLP HT

2D LiDAR for non-contact measurements on hot surfaces

► Measurement on surface temperatures < 1100°C

► Optimal measurement distance on hot surfaces 7 to 10 m

► Maximum range on cold surfaces 150 m

► 90° field of view

► High accuracy <5 mm

► Small spot size

► Fast pulse rate up to 60 kHz

► Tough and robust, IP67 certified

► Multi-echoes evaluation technology with up to 4 echoes

► Low power consumption

► Real time Ethernet

 

SLP HT specifications

Features

SLP HT

Range (m) @ R=100%

150

Range (m) @ R=10%

45

Optimal installation distance1 (m)

from 7 to 10

Surface temperature range2 (°C)

T ≤ 1100

Resolution (mm)

1

Repeatability 1 σ3 (mm)

8

Accuracy4 (mm)

≤ 5

Divergence (°) p x II5

0.076 x 0.029

Spot close to window (mm) p x II5

12 x 18

Focusing distance6 (m)

45

Scan angle (°)

up to 90

Multi-echo evaluation

up to 4

Scan rate (Hz)

selectable: 15 | 30 | 60

Measurements in 90° (points)

selectable: 2000 | 1000 | 500

Laser type

Pulse laser diode 905 nm

Laser Eye Safety Class7

1

Pulse rate (kHz)

up to 60

Interfaces

Ethernet TCP/UDP 100 Mb/s
RS232 Selectable Bauds, 8n1 (for 1PPS only)
Digital outputs 2 x 3.3 to 5 VDC programmable - Isolated switching outputs
Digital inputs 2 x 3.3 to 5 VDC programmable - Isolated inputs
External encoder inputs 3.3 to 5 VDC TTL input, channels A/B/Z

Power supply

24 VDC ± 5 VDC power supply

Power consumption (W)

12

Ingress Protection rating

IP67

Operating temperature

-30°C to +50°C

Storage temperature

-30°C to +70°C

Dimensions H x W x L (mm)

247 x 121 x 109

Weight (kg)

2.8

·  1 To reach the optimal performances in the measurements on hot surfaces, it is recommended to install the device at a distance between 7 meters and 10 meters from the target, with the laser beam hitting the target surface with the smallest incidence angle.

·  2 Thanks to the rough housing rated IP67, the SLP HT can operate in harsh environments in ambient temperatures of up to +50°C. In case the device needs to be installed in a warmer environment, a cooling system is recommended.

·  3 strong signal

·  4 systematic error, residual after removing the statistical error (Triple-IN procedure)

·  5 p: perpendicular to scan direction II: parallel to scan direction

·  6 when focussed to shorter range, spot sizes are smaller

·  7 Laser Eye Safety Class; EN 60825-1; 94,96,01

·  Specifications are subject to change. All data without tolerances are typical values.

Products

Download

Contattaci

Non esitate a contattarci, saremo lieti di soddisfare qualsiasi vostra richiesta di informazione di natura tecnica ed economica,relative alla nostra sensoristica.

Chiedi informazioni