Laser measuring device
Class 2 (660nm) 3A (650nm)
LDE
|
The LDE
sensors are based on the triangulation principle and can read distances and
thicknesses with pinpoint accuracy
Main advantages
Aluminium compact casing
Digital output RS232 - RS485 on request
Current analogue output standard, voltage analogue output on
request
Power supply 18 - 36Vdc, 120 mA
-
External Input Trigger TTL
-
Operating temperature -10...+60°C
|
Type |
Laser class |
Spot diameter mm
|
Stand off mm |
Working range mm |
Resolution linearity (1) |
Frequency max Hz (2) |
Analogue output (3) |
Digital output (3) |
|
LDE 11 |
2 |
<0,5 |
11 |
±1 |
0,0003mm
±0,002mm |
5.000 |
4 - 20mA
(0 - 10V) |
RS232
(RS485)
(CAN-BUS) |
|
LDE 15 |
2 |
<1 |
15 |
±5 |
0,05%FS
±0,1%FS |
2.000 |
4 - 20mA
(0 - 10V) |
RS232
(RS485)
(CAN-BUS) |
|
LDE 57.5 |
2 |
<2 |
57,5 |
±12,5 |
0,05%FS
±0,1%FS |
2.000 |
4 - 20mA
(0 - 10V) |
RS232
(RS485)
(CAN-BUS) |
|
LDE 105 |
2 |
<2 |
105 |
±25 |
0,05%FS
±0,1%FS |
2.000 |
4 - 20mA
(0 - 10V) |
RS232
(RS485)
(CAN-BUS) |
|
LDE 140 |
3A |
<2 |
140 |
±50 |
0,05%FS
±0,1%FS |
2.000 |
4 - 20mA
(0 - 10V) |
RS232
(RS485)
(CAN-BUS) |
|
LDE 355 |
3A |
<2 |
355 |
±125 |
0,05%FS
±0,1%FS |
2.000 |
4 - 20mA
(0 - 10V) |
RS232
(RS485)
(CAN-BUS) |
|
LDE 550 |
3A |
<2 |
550 |
±250 |
0,1%FS
±0,15%FS |
2.000 |
4 - 20mA
(0 - 10V) |
RS232
(RS485)
(CAN-BUS) |
| Note |
| (1) At working range, orthogonal
target, on white paper |
| (2) At best working conditions |
| (3) On request |
Dimensions
Download operating manual
Download configuration software
![[Immagine linea di divisione]](gif_images/div.gif)
Aggiornato il 10 dicembre 2004
|